Image(Up to 23kW of heat removal per rack)

Performance heat removal for high-density equipment in NetShelter SX and VX enclosures.

The only manageable rack heat removal solution.
High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, ducting it to the return air plenum and eliminating hot spots. Through automatic fan speed adjustment based on temperature or power consumption, the fans will self-adjust for optimal performance. With a unit-mounted LCD display users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit SX. This space-saving product mounts to the back of either the NetShelter SX or VX enclosure - requiring zero U space.

Features & Benefits

Network manageable
View the user interface with a browser. Gives quick access from anywhere on the network

InfraStruXure Manager compatible
Enables centralized management via the APC InfraStruXureÆ Manager.

Temperature monitoring
Allows up to 3 remote sensors to monitor rack inlet temperature.

LCD display
Accessible without opening the door for easy operation. Allows user to locally monitor and control the unit.

Redundant fans
In the event of a fan failure, remaining fans will speed up and provide airflow up to 1500 CFM.

Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.

Ducted Exhaust System
Removes hot air from the data center to prevent re-circulation and eliminate air mixing.

Field replaceable components
Fans and electronics module can be readily replaced without uninstalling the unit.

Adjustable mounting frame
The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights.

Zero "U" Solution
Mounts to the rear of the rack, leaving valuable rack space for other equipment.

Easy to install
Innovative design allows for fast, easy installation by almost anybody.

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Increased capacity
Higher rate of heat removal allows more equipment to be installed in each rack.

 
 
 