For Expert Configuration Assistance, Pricing, and Availability, Please Call (800) 365-8816
(Available with four heat rejection methods: Air, Water, Glycol, and Chilled Water. MultiCool and Economizer are available in North America only.)
Modular Floor Mount Precision Air Conditioning for environmentally sensitive equipment areas.
The world's only computer room air conditioning system built on twenty-first century technology.
The NetworkAIR FM utilizes leading edge precision air technologies. Modular construction, variable frequency drives, dedicated de-humidification, tandem scroll compressors, and front service access are all integrated into one high efficiency system. A scalable design enables customers to meet the changing needs of their environments.
Features & Benefits
Availability
Tandem scroll compressors
Quiet and efficient operation of scroll compressors, connected on a common circuit for staged capacity control (N/A chilled water systems).
Direct drive motors
Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Variable Frequency Drives
Enables the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention.
Steam humidifier
Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance.
†
Serviceability
Front service access
The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
†
Manageability
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Redundant group control
Allows up to 4 groups of precision air conditioners to communicate with each other for redundancy, demand fighting prevention, mode assist, and global sharing of certain settings.
Programmable input/output contacts
Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.
Network interface
Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
Dew point humidity control
Humidification control can be set to dew point control instead of relative humidity control. Warmer return air temperatures can result in over-humidification when set for relative humidity control. Dew point control uses the moisture content of the air for humidification demand.
Audible alarms
Audible alarms (beeps) that notify end-users of the following conditions: On-Battery, Low Battery, and Replace Battery. Audible alarms are integrated in the following PowerShield models: CP27U13, CP27B13, CPL34U12, and CP16U48. Audible alarms are available for other PowerShield models through an external accessory. Audible alarms can be silenced for 24 hours by pressing the Alarm Silence Button.
†
Protection
Air Filtration
Removes dirt and other particulates from the intake air for cleaner supply air.
Double-walled panels Separates insulation from the air stream, which prevents periodic maintenance of the insulation and reduces noise levels. Small particles of insulation can be picked up by the air stream if not isolated.
†
Economy
Dedicated dehumidification
Boosts system efficiency by adding latent capacity without overcooling or increasing the requirement for reheat (N/A chilled water systems).
SCR electric reheat